Contact Us
All
Articles
Recent Searches
Clear all
No recent searches
Popular Articles
Articles
View all
Topics
View all
Tickets
View all
Sorry! nothing found for
Submit a ticket
My Tickets
Login
Vscan Air ™
Solution home
Vscan Air - Know Your Device
About Vscan Air
Vscan Air - Know Your Device
About Vscan Air
Quick Demo Overview
About Vscan Air
Specifications
System Components
Accessories
Vscan Air Battery
Battery Specification
Charging Vscan Air
Battery Level Indicator
Vscan Air Probe LED Indication
Vscan Air Probe
Probe Description
App Controls Overview (Status Indicators)
Environmental Requirements
Maximum Probe Temperature
Vscan Air- AI tools
Caption AI
Launch Vscan Air using Caption Care
Lung Guidance
AutoAS
Auto Bladder Volume - overview
Vscan Air CL Auto bladder volume
Vscan Air SL Auto bladder volume
Bladder Volume settings
Vscan Air - Digital Tools
My DeviceHub
Verisound Gallery solution
MyRemoteShare, powered by Zoom
Vscan Air - Getting Started
Supported Display Devices
Vscan Air - Compatible Display Devices
Display Device Minimum Requirements
Initial use
Power ON/OFF
Vscan Air App Installation
Pairing Vscan Air Probe with your Device
Vscan Air Pairing Tips and Tricks
Display Device Image Quality Verification
Activation and Registration
Vscan Air Installation & Registration
Vscan Air - First Time Registration
Vscan Air App Registration Using An Existing Account
Vscan Air Probe Registration Using Existing Account
Vscan Air app registration using an Enterprise Single Sign-On (SSO) user account
Scan as a Guest User
Adding New Users
Data Access PIN and Biometric Authentication
Changing Data Access PIN
Preview Mode
Unregister Vscan Air Probe
Unregister Vscan Air App
Vscan Air Configuration
Configuration
Diagnostics
Subscriptions and licenses
About
My account (Update / Delete)
Additional Support
Using Vscan Air
Display Features
Black/white imaging (B-mode)
Left / Right Panel
Barcode Scanner
Scanning Recommendations
General Scanning Recommendations
Use of Gel
Probe Orientation
Image Crop Indicator
Patient Examination
Creating a new examination
Vscan Air Probe and Presets
Probes and Presets
Changing the Preset and Probe
Select a default preset
Scanning Modes
Black/White Imaging (B-mode) adjustments
M-mode (Motion mode)
Color Flow (Color Doppler)
Color Imaging Scanning Adjustments
Pulsed Wave (PW) Spectral Doppler
Optimising PW Doppler settings
Storing Image/Video
Store Images and Video clips
Setting default duration for capturing videos
Assign patient data to current / existing exam
Assign patient data from MWS to current / existing exam
Measurements
Basic Measurements
M-mode measurements
PW-mode measurements
OB (Obstetric) measurement
OB (Obstetric) Worksheet/Report
Annotations
Annotating an image
Edit / Reposition / Delete an Annotation
Review / Recall Of Stored Data
Review and Recall images
Audit logs
Export Data
Export Data (Share Images)
Export Data To The DICOM Image Server
Secure DICOM
Export data to MPPS Server
Export Data To The Network Shared Folder
Network Shared Folder Structure
Using Vscan Air
Using in environments where time is critical
Configure the device for emergency environments
When charging options are limited or unavailable
Scanning for foreign bodies
Storing devices in between uses
Putting the probe into Storage mode
Preparing For A Guided Procedure With Vscan Air
Preparing for a guided procedure
Assessing Display Device Wi-Fi Performance with Vscan Air Probe
General Considerations
Setting Up Device For Procedure
Vscan Air - Maintenance & Troubleshooting
System Care & Maintenance
System Care And Maintenance
Upgrade Software
Probe Errors
Diagnostics Test
Transducer Element Test
Contact information
Cleaning And Disinfection
Cleaning And Disinfection
Probe Reprocessing
General Troubleshooting
No connection between Probe and Device
Troubleshoot the Vscan Air probe
Troubleshoot Probe Pairing
Troubleshoot Probe connection
Troubleshoot subscriptions
Troubleshoot Server settings
Troubleshoot Network Shared Folder
Troubleshoot DICOM
Troubleshooting FAQs for Digital tools
Troubleshooting – Brazilian Portuguese (iPhone and iPad)
Alternative installation method for Vscan Air Mobile App on Android
Troubleshoot: Pairing & Connectivity
Troubleshoot: Pairing & Connectivity
Probe LEDs simultaneous white flash until automatic shutdown
Probe LED steady white, app never proceeds to scanning
Probe LEDs steady white for a short time, but return to flashing
Mobile device connects to the wrong probe
Probe LEDs steady blue, app never proceeds to scanning
Probe LEDs turn purple(magenta), shuts down during connection
Probe LEDs show one steady blue (the other off), will not connect (or my probe has not shut off after 5 minutes of inactivity)
Yellow dot shown on the Wi-Fi Quality indicator (or scanning is lagging/stuttering)
Vscan Air - Connectivity
Server Settings
Configure Modality Worklist Server
Configure DICOM Image Server
Configure MPPS server
Storage Commit
Configure Network Shared Folder
Configure DICOMweb server
Configure Syslog server
Delete Server
Android Wi-Fi Direct
FAQs
Clinical FAQs
What does the ‘yellow’ symbol on the wireless connection quality indicator mean?
What are the frequency and depth ranges on the transducers? What is the shallowest depth on the linear transducer?
What do the arrows on B-mode and CF mode in the app indicate?
Display Devices FAQs
Is there a change in image resolution when using different mobile devices?
Are the mobile device batteries depleted more quickly while scanning?
Can the mobile device software be updated without impacting the performance of Vscan Air when mobile device manufacturers release software updates?
How will I be notified of app updates? Will I need to buy a new probe?
App and Display Devices FAQs
Can Vscan Air connect to monitors, PCs, other Windows based devices?
Is it possible to take screenshots with Vscan Air? (How can we minimize the risk of compromising sensitive patient data by way of screen-shots?)
Where are the images saved on the Vscan Air app?
How many display devices can I use with my Vscan Air probe?
How much hard drive space do the images take?
Probe FAQs
Does the Vscan Air probe heat up while scanning?
How long can I scan with Vscan Air?
Are probe covers available for use with Vscan Air?
Connectivity & Data Management FAQs
Can I scan without an Internet connection?
Do images delete automatically?
Is an Internet connection required for the registration process?
What are the data export options on the Vscan Air?
How can I manage multiple apps and probes at a hospital? (Mobile Device Manager, etc.)
What are the probe to app connectivity options?
What does “Your institution’s mobile device manager controls the content on your device” mean?
Can we export images to Tricefy™?
Can you turn off the archive option on the Vscan Air?
Does patient information come over on DICOM® and Network file share?
Is there a way to block being able to share images through social media from the Vscan Air app?
Is there an “auto send” feature with DICOM® or Network Share?
Privacy & Security FAQs
How secure is the stored patient information on a mobile device?
What happens when the lock/password on the mobile device is removed?
Can the use of private mobile devices be restricted in public institutions? (i.e. can a user be prevented from pairing a probe to their private phone without prior permission?)
System Care & Maintenance FAQs
How should I disinfect/clean my personal mobile device?
What cleaning/disinfection methods are compatible with Vscan Air?
Intended Use FAQs
Can Vscan Air be used in Ambulances and Air Ambulances like the Vscan Extend*?
The lifetime of battery is specified with “at least 500 charges”. What happens after 500 charges?
What function does the “grey button” on curved transducer side have?
Is there a way to back up data?
Does export to shared network folders work with Apple OS computers?
Digital Tools FAQs
Registration and Sign-in
General Digital Tools FAQs
MyDeviceHub
MyImageCloud
MyRemoteShare
Open navigation
Quick Demo Overview
Articles in this folder
Quick Demo Overview
About Vscan Air
Specifications
System Components
You may like to read
System Components
Data Access PIN and Biometric Authentication
Vscan Air Installation & Registration
App Controls Overview (Status Indicators)
Auto Bladder Volume - overview
Accessories
System Care And Maintenance
Review and Recall images
X
0 of 0